独立式电气火灾监控探测器的使用范围
独立式电气火灾监控探测器,在大型场所可直接接入电气火灾监控系统中去使用,而在无消防控制室且电气火灾监控探测器设置数量不超过4个时,则可以采用独立式电气火灾监控探测器来使用。
The independent electrical fire monitoring detector can be directly connected to the electrical fire monitoring system for use in large-scale places, while the independent electrical fire monitoring detector can be used when there is no fire control room and the number of electrical fire monitoring detectors is no more than 4.
在设置有火灾自动报警系统的建筑中,独立式电气火灾监控探测器的报警信息,若是接入火灾自动报警控制器或消防控制室图形显示装置显示,则其报警信息显示应与火灾报警信息显示有明显区别。严格地说按照《电气火灾监控系统的设计方法》的要求(暂行规定),当并入火灾自动报警系统时,应采用独立显示器。
In buildings equipped with automatic fire alarm system, if the alarm information of independent electrical fire monitoring detector is connected to the automatic fire alarm controller or the graphic display device in the fire control room for display, its alarm information display shall be distinct from the fire alarm information display. Strictly speaking, in accordance with the requirements of design method for electrical fire monitoring system (Interim Provisions), when it is incorporated into the automatic fire alarm system, independent display shall be used.
在未设置火灾自动报警系统的建筑中,独立式电气火灾监控探测器应配接火灾声光警报器来使用,在探测器发出报警信号时,应自动启动火灾声光警报器。
In buildings without automatic fire alarm system, the independent electrical fire monitoring detector shall be equipped with fire audible and visual alarm to use. When the detector sends alarm signal, it shall automatically start the fire audible and visual alarm.
在非重要供电场所,独立式电气火灾监控探测器发出报警信号后,可以在经过一段延时后,切断供电电源。
In non important power supply places, the independent electrical fire monitoring detector can cut off the power supply after a period of delay after sending out the alarm signal.